PA6 K224-G3荷兰D***---K224-g3 is a kind of polyamide 6 (nylon 6) material, which contains 15% glass fiber reinforced material. The product is available in North America, Europe or Asia Pacific region, and the processing method is injection molding. The main characteristics of akulon? K224-g3 are: flame retardant / rated flame.
Unit system test method for physical properties after drying and adjustment
Density: 1.23 -- g / cm? ISO 1183
Shrinkage: ISO 294-4
Vertical flow direction 0.96 --% ISO 294-4
Flow direction: 0.32 --% ISO 294-4
Water absorption ISO 62
Saturated, 23 ° C 7.6 --% ISO 62
Balanced, 23 ° C, 50% RH 2.3 --% ISO 62
Mechanical properties - unit system test method after drying and adjustment
Tensile modulus 6000 3500 MPa ISO 527-2
Tensile stress (fracture) 125 70.0 MPa ISO 527-2
Tensile strain (fracture) 3.0 12% ISO 527-2
Bending modulus 5200 -- MPa ISO 178
Bending stress 170 -- MPa ISO 178
Impact performance - unit system test method after drying and adjustment
Notched impact strength of simply supported beams ISO 179 / 1ea
-30°C 6.0 6.0 kJ/m² ISO 179/1eA
23°C 7.0 15 kJ/m² ISO 179/1eA
Notchless impact strength of simply supported beams ISO 179 / 1eu
-30°C 40 40 kJ/m² ISO 179/1eU
23°C 45 80 kJ/m² ISO 179/1eU
Unit system test methods for thermal performance, drying and conditioning
Hot deformation temperature
0.45 MPa, UN annealed 215 - - C ISO 75-2 / b
1.8 MPa, UN annealed 195 - - C ISO 75-2 / A
Melting temperature: 1 220 - - C ISO 11357-3
Linear coefficient of thermal expansion ISO 11359-2
Flow 3.0e-5 -- cm / cm / ° C ISO 11359-2
Transverse 8.0e-5 -- cm / cm / ° C ISO 11359-2
Unit system test method for electrical performance after drying and adjustment
Surface resistivity - 1.0e + 14 ohms IEC 60093
Volume resistivity: 1.0e + 15.1.0e + 15 ohms · cm IEC 60093
Dielectric strength 35.25 kV / mm IEC 60243-1
Relative permittivity IEC 60250
100 Hz 3.50 14.0 IEC 60250
1 MHz 4.70 4.50 IEC 60250
Dissipation factor IEC 60250
100 Hz 5.5E-3 0.15 IEC 60250
1 MHz 0.018 0.12 IEC 60250
Leakage tracking index -- 600 V IEC 60112
Unit system test method for flammability, drying and adjustment
Flammability class - IEC 60695-11-10, - 20
0.750 mm HB -- IEC 60695-11-10, -20
1.50 mm HB -- IEC 60695-11-10, -20