Technical Data  
  • According to DIN VDE 0816
  • Temperature range
    flexible -20°C to +50°C
    fixed installation to +70°C
  • Loop resistance at 20°C
    0,6 mm = max. 130 Ohm/km
    0,8 mm = max. 73,2 Ohm/km
  • Operating voltage (peak voltage)
    max. 225 V
  • Test voltage
    conductor/conductor U eff. 500²)
    conductor/shield U eff. 2000 V
  • Insulation resistance
    min. 5 GOhm x km
  • Line attenuation
    of side circuits at 800 Hz
    0,6 mm = 1,04 dB/km
    0,8 mm = 0,78 dB/km
  • Impedance
    of side circuits at 800 Hz
    0,6 mm = 720 Ohm
    0,8 mm = 520 Ohm
  • Minimum bending radius
    approx. 10x cable Ø
  • Radiation resistance
    up to 80x106 cJ/kg (up to 80 Mrad)
  • Caloric load values
    see Technical Information
 
 
 
Part-No. Description & No. of Pairs x Diameter in mm Outer Ø (mm) Cop. weight
kg/km
Weight
kg/km
AWG
34007 A-2YF(L)2Y 2X2X0,6 7.5 11.0 80.0 -
34008 A-2YF(L)2Y 4X2X0.6 9.0 23.0 140.0 -
34009 A-2YF(L)2Y 6X2X0.6 12.0 34.0 150.0 -
34010 A-2YF(L)2Y 10X2X0.6 13.5 57.0 190.0 -
34011 A-2YF(L)2Y 20X2X0.6 16.0 113.0 310.0 -
34012 A-2YF(L)2Y 30X2X0.6 19.0 170.0 430.0 -
34013 A-2YF(L)2Y 40X2X0.6 20.5 226.0 545.0 -
34014 A-2YF(L)2Y 50X2X0.6 23.0 283.0 660.0 -
34015 A-2YF(L)2Y 70X2X0.6 26.0 396.0 895.0 -
34016 A-2YF(L)2Y 100X2X0.6 31.5 565.0 1230.0 -
34017 A-2YF(L)2Y 150X2X0.6 37.5 848.0 1780.0 -
34018 A-2YF(L)2Y 200X2X0.6 42.5 1131.0 2320.0 -
34036 A-2YF(L)2Y 250X2X0,6 47.5 1414.0 2910.0 -
34037 A-2YF(L)2Y 300X2X0,6 51.5 1696.0 3490.0 -
34038 A-2YF(L)2Y 350X2X0,6 55.0 1979.0 3970.0 -
34039 A-2YF(L)2Y 4002X0,6 60.5 2262.0 4480.0 -
34040 A-2YF(L)2Y 500X2X0,6 66.0 2827.0 5460.0 -
34029 A-2YF(L) 2Y 2X2X0,8 8.5 20.0 100.0 -
34030 A-2YF(L) 2Y 4X2X0,8 10.0 40.0 180.0 -
34019 A-2YF(L)2Y 6X2X0.8 12.5 60.0 190.0 -
34020 A-2YF(L)2Y 10X2X0.8 15.0 101.0 280.0 -
34021 A-2YF(L)2Y 20X2X0.8 19.0 201.0 480.0 -
34022 A-2YF(L)2Y 30X2X0.8 23.0 302.0 670.0 -
34023 A-2YF(L)2Y 40X2X0.8 26.0 402.0 860.0 -
34024 A-2YF(L)2Y 50X2X0.8 29.0 503.0 1060.0 -
34025 A-2YF(L)2Y 70X2X0.8 33.0 704.0 1420.0 -
34026 A-2YF(L)2Y 100X2X0.8 39.0 1005.0 1980.0 -
34027 A-2YF(L)2Y 150X2X0.8 47.0 1508.0 2940.0 -
34028 A-2YF(L)2Y 200X2X0.8 51.0 2011.0 3780.0 -
34031 A-2YF(L)2Y 250X2X0,8 58.0 2514.0 4660.0 -
34032 A-2YF(L)2Y 300X2X0,8 62.5 3016.0 5570.0 -
34033 A-2YF(L)2Y 350X2X0,8 68.0 3519.0 6750.0 -
34034 A-2YF(L)2Y 400X2X0,8 73.0 4022.0 7630.0 -
34035 A-2YF(L)2Y 500X2X0,8 81.5 5027.0 9540.0 -
 
Cable Construction  to top up arrow
  • Bare copper conductor, solid, 0,6 and 0,8 mmØ
  • PE (2Y) conductor insulation, wall-thickness as per DIN VDE 0816 table 4
  • Conductor identification of quads marked with black rings
  • 4 conductors twisted to a star quad
  • 5 star quads stranded to sub units,
    each 5 or 10 sub units stranded to main units and the sub or main units stranded to cable conductor
  • Conductor cavities continuously filled with petrol-jelly
  • Conductor wrapping with paper tape
  • Outer jacket, as laminated jacket (L)2Y, PE-coated aluminum tape spliced with PE (2Y) jacket
  • PE-outer jacket color black
  • Jacket marking continuously with telephone-receiver, meter marking in white color
Properties  to top up arrow
  • These cables are not allowed for purposes of high current and power installation. These cables with outer PE-jacket are also not permitted for fire and explosive areas without any protective measure.
  • Mutual capacitance at 800 Hz
    of all values100%
    0,6 mm - max. 52 nF/km
    0,8 mm - max. 55 nF/km
    of all values 95%
    0,6 mm - max. 50¹) nF/km
    0,8 mm - max. 53¹) nF/km
    of all values 80%
    0,6 mm - max. 48 nF/km
    0,8 mm - max. 50 nF/km
  • Capacitance unbalances at 800 Hz
    of all values k1 100% - max. 800¹) pF/300 m
    of all values k1 98% - max. 400 pF/300 m
    of all values k9 - 12 100%-max. 300¹) pF/300 m
    of all values k9 - 12 98% - max. 100 pF/300 m
Note  to top up arrow
  • ¹) But at least for 2 quads.
  • ²) Local cables with more than 100 pairs the test conductor/conductor is emitted.
  • Conductor Ø 0,4 mm on request.
Application 
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone exchange or central offices and as well as for industrial plants.
These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits - and also for indoor-laying.
Both sides of PE-copolymer coated aluminum type (L), which is spliced with the outer PE-jacket ensures a barrier against water vapor and diagonally water-proof.
Black colored PE-jacket is UV-resistant.
The Polyethylene material (PE 2Y) is halogen-free.
CE Approval = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.