CDW-100T Series Impact Testing Machine Low Temperature Meter is our company according to GB229-94 center but the to be newer than to the low temperature installment request development compressor refrigeration equipment. This equipment uses many type compressor refrigeration technology, stirs the way using the thermal equilibrium principle and the circulation, achieved to test specimen automatic uniform cooling, c***tant temperature, this equipment operation simple convenient, the working efficiency is high, is in the metal low temperature impact test the most ideal test specimen cools, the heat preservation equipment. Simultaneously also may use in other low temperature examinati*** and the test work. Can meet requirments of GB-229-2002, EN10045-2, E23-02A and so on.
Main Technical Parameter:
1. Cooling Range: +30~100(-110) (room temperature≤25)
2. C***tant temperature accuracy: <0.5
3. Cooling speed:
+30~0 about2.0 min
0~-20 about 1.5 min
-20~-60 about 1min
-60~-110 about 0.7min
4. Max. Dimension: 1500*1200*1200mm
5. ***ailable working place: 150*150*240mm
6. Specimens numbers: >200(Impact Specimens Size: 10*10*55mm)
7. Whisk Motor: 12W
8. Power: 220V~240V, 50Hz, 7KW
9. Control Precision: 0.1
10. Digital timer: 1min100min, Resolution: 1min;
11. Digital timer temperature precision: 0.01, Resolution: 0.01
12. Cooling medium: Alcohol or other unfrozen liquid
13. Double whisk motors: Make the cooling medium play, in order to specimens uniformity cooling
14. Handle desk is make of stainless steel.
15. France Taikang compressor.
16. Match automati*** cleanout specimens device, inner is stainless steel.
17. Specimens basket is net stainless steel.
18. Continuable working up to 10 hours
19. Collocate: Specimens basket, Specimens jaw
Main Technical Parameter:
1. Cooling Range: +30~100(-110) (room temperature≤25)
2. C***tant temperature accuracy: <0.5
3. Cooling speed:
+30~0 about2.0 min
0~-20 about 1.5 min
-20~-60 about 1min
-60~-110 about 0.7min
4. Max. Dimension: 1500*1200*1200mm
5. ***ailable working place: 150*150*240mm
6. Specimens numbers: >200(Impact Specimens Size: 10*10*55mm)
7. Whisk Motor: 12W
8. Power: 220V~240V, 50Hz, 7KW
9. Control Precision: 0.1
10. Digital timer: 1min100min, Resolution: 1min;
11. Digital timer temperature precision: 0.01, Resolution: 0.01
12. Cooling medium: Alcohol or other unfrozen liquid
13. Double whisk motors: Make the cooling medium play, in order to specimens uniformity cooling
14. Handle desk is make of stainless steel.
15. France Taikang compressor.
16. Match automati*** cleanout specimens device, inner is stainless steel.
17. Specimens basket is net stainless steel.
18. Continuable working up to 10 hours
19. Collocate: Specimens basket, Specimens jaw
Contact: Andy
MSN messenger: jn-xuxiaowei@
E-mail:testmachinery@
Mob: 86-159-63130664, Fax: 86-531-68816878