企业资质

北京伊普瑞斯科技有限公司

普通会员18
|
企业等级:普通会员
经营模式:
所在地区:北京 北京
联系卖家:
手机号码:
公司官网:www.express-cn.com
企业地址:
本企业已通过工商资料核验!
企业概况

伊普瑞斯科技有限公司凭借所推荐产品的技术优势和日趋扩大的服务网络,全面致力于世界领先的生命科学、生物化学、临床诊断、制药、环境科学以及食品安全检验用等研究和生产领域的消耗试剂及生产原材料在中国地区的推广、宣传和技术服务。...

活性碳埋藏剂

产品编号:2788492                    更新时间:2020-08-12
价格: 来电议定
北京伊普瑞斯科技有限公司

北京伊普瑞斯科技有限公司

联系人名片:

联系时务必告知是在"产品网"看到的

产品详情

活性碳埋藏剂

Active Carbon-impregnated Silica Gel
Grade: for Dioxin Analysis
Storage condition: Keep at RT.
规格:10g
Summary
This product is for research use only.  Do not administer it to human.
Applicable to pretreatment (cleanup) in dioxin analysis!
Active Carbon-impregnated Silica Gel is a column clean-up filler developed for microanalysis of polychlorodibenzo-p-dioxin (PCDDs) and polychlorodibenzofuran (PCDFs).
Attaining high microanalysis precision requires excellent clean-up method.  As dioxins are particularly high in toxicity, the very cause of social concern, it is a must to secure high reliability in its analysis value.
Active carbon has a characteristic of specifically adsorbing compounds with flat board structures, such as dioxin.  It is gaining a global-wide recognition that active carbon clean-up process is an essential requirement in refining dioxins.  However, conventional active carbon had such weaknesses as low penetrability when used as fine particles and poor tailing at elution when the particle is large.
This new type of column chromatography filler, made by impregnating fine-grain active carbon into silica gel, not only has the excellent characteristics of active carbon but also has good penetrability.
[Operating procedure]
Lay glass wool at the bottom of chromatography tube attached with a stop cock and place in anhydrous sodium sulphate at the height of about 1 cm.
Then place in 1g of active carbon impregnated silica gel and lightly shake the column to fix its thickness.  Again place in another layer of anhydrous sodium sulphate on top at a height of about 0.5 cm.  (Refer to the equipment drawing.)

When column setting is complete, immediately let the specimen flow down gently (hexane solution concentrated to about 0.3 mL is desirable) onto the anhydrous sodium sulphate layer, using a pipette.  Then wash off the tube wall and anhydrous sodium sulphate layer a few times with 0.1 mL of hexane.

After le***ing at rest for a few minutes, connect a separatory funnel containing 200 mL of 25% ***ane/hexane [v/v] mixture to the upper part of chromatography tube and gently let the mixture flow down so spreading starts at the flow rate of 1 drop per second.  (This effluent does not contain dioxin.)

When the ***ane/hexane mixture is exhausted, continue performing elution using 200 mL of toluene at the flow rate of 1 drop per second. (This effluent contains dioxin.)

Concentrate the toluene effluent to the target volume using pressure reducing KD concentrator.
[Note]
PCBs are completely eluted in the 25% ***ane/hexane effluent ready to be supplied for quantitative analysis.
Due to the dry type column chromatography, bubbles remain in the column during the elution process.  However no adverse effect is seen in the recovery percentage and reproducibility.

The recovery percentage is more than 90% with loads of 1 ng for each 1,2,3,4-T4CDD and O8CDD.
T4CDD : Tetrachlorodibenzo-p-dioxin O8CDD : Octachlorodibenzo-p-dioxin1)
[Reference]
Ono, M., Wakimoto, T., Tatsukawa, R. and Masuda, Y.: Chemosphere, 15, 1629 (1986).

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    如有更多其它***产品需求与查询,请及时接洽:info@express-cn.com 或在我公司查询主页客户留言处(http://www.express-cn.com/expressgb/m)留下您的查询内容,我们即会在当天为您作出回复。

伊普瑞斯科技有限公司
info@express-cn.com
在线***:***:1069267096
          MSN:liyuqiu1983@
              cindylee-1981@
总机:010-60206266
传真:010-60206773
www.express-cn.com

北京伊普瑞斯科技有限公司电话:传真:联系人:

地址:主营产品:化学试剂

Copyright © 2025 版权所有: 产品网店铺主体:北京伊普瑞斯科技有限公司

免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责。产品网对此不承担任何保证责任。