Line Leakage Tester Series AI5000
l conform to , acc. to EN 50 191
l Measuring circuit acc. To EN 60 990 fig. 4
l external power supply
l internal increase of voltage to 110%
l for 1-and 3-phase DUTs
l digital 24 VDC and analogue interface
Data
|
AI 5000A
|
AI 5001A
|
AI 5000P
|
AI 5010D
|
Output (230V/50Hz) Output (115V/60Hz) – potential – phases
|
230 V – 256 V / 16 A 115 V – 128 V / 16 A power supply 1
|
230 V – 256 V / 16 A 115 V – 128 V / 16 A power supply 1
|
60 V – 300 V / 2 A 30 V – 150 V / 4 A free1
|
3 × 400 V / 16 A 3 × 200 V / 16 A power supply 3
|
operating modes
|
A1 / A2 / B
|
A / B
|
A / B
|
A1 / A2 / A3 / A4 / B
|
recognition phase
|
yes
|
yes
|
no
|
no
|
measuring range
|
1 mA / 10 mA
|
|
||
interruption when changing mode of operation
|
yes
|
no
|
no
|
no
|
plug-in
|
19“ / 4 HU
|
19“ / 4 HU
|
19“ / 4 HU
|
19“ / 8 HU
|
power supply
|
230 V / 50 Hz or 115 V / 60 Hz
|
400 V / 50 Hz
|
||
|
|
or 200 V / 60 Hz
|
Special features
l conform to CE, in accordance with EN 50 191 • optical and audible alarm
l analogue measuring instrument for voltage, class 1.5
l analogue measuring instrument for current, class 1.5
l potential free PLC remote control interface
l potential free analogue output for voltage (0 up to 10 VDC)
l potential free analogue output for current (0 up to 10 VDC)
l external power supply for test voltage (not in case of AI 5000P)
l built-in, adjustable voltage increase from 100% up to 110% (not in case of AI 5010D)
Opti*** / Optional
l measuring range 0.1 mA / 1 mA (AI 5000P only)
l test current 32 A (AI 5010D only)