Model Name IM12-02B-N-ZW0 Part No. 6021124 Features Sensing range Sn: 2 mm Installation in metal: Flush Switching frequency: 1,200 Hz Connection type: Cable, 2-wire, 2 m Switching output: NAMUR Enclosure rating IP 67 1) Switching mode: NCC 1) According to EN60529 Mechanics/electronics Design: cylindrical Housing length: 30 mm Supply voltage 7.5 V DC ... 25 V DC 1) Power c***umption ≤ 30 mA 2) Hysteresis: 1 % ... 15 % Temperature drift (of sr): &plu***n; 10 % EMC: Nach EN 60947-5-6 Cable material: PVC Conductor cross-section: 0.34 mm² Cable diameter: 4.9 mm Housing material: Metal, Nickel-plated brass Housing cap: Plastic, PBT Max. tightening torque: 7 Nm Thread size: M12 x 1 EC type approval certificate: PTB 03 ATEX 2037 Hazardous area category: 1G, 2G Marking of the unit: II 1 G Ex ia IIC T6 Ta: -20 °C ... +55°C, II 2 G Ex ia IIC T6 Ta: -20 °C ... +70 °C Thread lenght: 29 mm Power c***umption, attenuated: ≤ 1 mA Power c***umption, unattenuated: ≥ 2.2 mA Cable resistance: 50 Ω Input voltage Ui max 15 V 3) Input power Pimax. 120 mW 4) Input current Ii max 50 mA 5) Internal capacitance Ci max. 140 nF 6) Internal inductance Li max. 340 µH 7) Nominal voltage: 8.2 V DC 1) 2) When used outside the hazardous area 3) 4) 5) 6) 7) Ambient data Ambient temperature, operation: -20 °C ... 70 °C Shock/vibration stress: 30 g, 11 ms/10 ... 55 Hz, 1 mm |