联系人:吴萃真
电话:13524520301
Q Q:576539997@***.com
MULTIDRIVE-3PH Universal 3 Phase Thyristor unit up to 2700A General Description ß MULTIDRIVE is a Full digital and universal Thyristor unit based on a very powerful dedicated micro configurable via serial communication port for all inputs, firing modes, feed back modes and loads types. ß Suitable to drive resistive, inductive, transformer and complex loads requiring current limit, power feedback or particular algorithm. ß Frontal Key Pad standard to configure all the internal functi*** and parameters. ß Four Analog output configuirable ß Six Digital input ß Four realay output ß Universal Input signal with automatic zero/span calibration. ß Universal Firing modes, customer configurable via Key Pad or communication port as Burst Firing and Phase Angle. ß Universal Feed back modes ß Soft Start can be used in addition to Burst Firing and Phase Angle. ß Unbalanced load and Heater Break Alarm. ß RS 485 port. Modbus prot
概述
适用于电阻、电感和变压器负载
电流范围-35A、45 A、75 A、100A、125A、225A、300 A、350A、400 A、450A、500 A、600 A、850A、1000 A、1400 A、1500 A、1850A、2000 A、27 000 A
电源电压高达480V作为标准,600伏和690V可供选择
基于微处理器的电子电路与电源完全隔离
射击方式包括爆发射击(BF)、单周期(SC)、软启动+突发射击(S+BF)、延迟触发+突发射击(Dt+BF)、相位角(PA)、软启动+相位角(S+PA)。
输入信号从4-20mA,0至10V直流线性输入,10K锅或RS485通信
可选的控制模式包括V,I,VXI,V2
限流标准,包括内部电流互感器,通过前面板小键盘完全可调
模拟输入电流限值分析
加热器断开(HB)报警,用自动设定、继电器报警输出和前LED指示来诊断部分或总负载故障。
4个可配置模拟输出,4个继电器输出和6个数字输入作为标准
内部快速熔断器作为标准
RS485通信(Modbus协议)标准
临界报***视相位损失、旋转和提供热保护
具有高耗散值的特殊设计散热器
IP20保护符合CE规范,CUL待定
Thyristor Power Controller - Multidrive 3PH, up to 2700A
Load......Resistive, Inductive, Transformer and Complex Load types requiring Current Limit
Input......4-20mA, 0-10Vdc, 10K Pot, RS485 Comms
Firing......Burst, Single Cycle, Delayed Triggering,Phase Angle, Soft Start
Voltage...24Vac to 690Vac Supply
Multidrive is a fully digital and universal Thyristor Power Controller designed to drive most load types. ***ailable in 21 Amp sizes from 35A to 2700A the Multidrive provides the user with optimum control of the process and ease of set-up & maintenance. The Front panel keypad & display allows total flexibility for the user with full configuration of the process & digital inputs types and firing & control modes, to suit the application. Real time values such as the Voltage, Current & Power can be read from the display. Internal quick-blow fuses as standard provide complete protection for the thyristor. Additional features such as current limit, profiling, heater break alarm and RS485 comms come as standard.
For 3 wire configurati*** which do not include a neutral connection see our Multidrive 2 Phase SCR Controller