KFD2-ST***-Ex2
***ART Tran***itter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire ***ART tran***itters, Output 0/4 mA ... 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-STV4-Ex1-1
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-FF-232
RS 232 Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), RS 232 input/output, Transfer direction: to the control system
KFD2-SCD2-2.LK
***ART Current Driver
2-channel signal conditioner, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-SCD2-Ex1-Y1
***ART Current Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-SCD2-Ex2-Y1
***ART Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
KFD2-SL2--Y1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Increased input load, Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 10 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SOT2--Y181008
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
KFD2-STV4-Ex1.2O-2
***ART Tran***itter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/2 V ... 10 V, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-UT2-2-1
Universal Temperature Converter
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511, Rated voltage: 20 ... 30 V DC
KFD2-CR4-1
Tran***itter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire tran***itters and 2-wire current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-CR4-1.2O
Tran***itter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire tran***itters and 2-wire current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Accuracy 0.1 %, Up to SIL3 acc. to IEC 61508, Rated voltage: 20 ... 32 V DC
KFD2-SH-Ex1.T
Switch Amplifier
1-channel isolated barrier, 24 V DC supply, Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
KFD2-SH-Ex1.T.OP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
KFD2-ST***-1
***ART Tran***itter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-ST***-1.2O
***ART Tran***itter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-ST***-2
***ART Tran***itter Power Supply
2-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire ***ART tran***itters, Output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC
KFD2-SL2-.1270
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 70 mA at 12.5 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-ST***-1.2O-3
***ART Tran***itter Power Supply, Output Current Sink
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire ***ART tran***itters and 2-wire ***ART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC