Automatic GD-2801I Needle Penetration Test
The Needle Penetration Test is designed and made as per the National Standard GB/T 4509 “Test Methods for Needle Penetration of Petroleum Asphalt”, and T0604 “Asphalt Needle Penetration Test” in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. The Automatic Needle Penetration Test is suitable to determine needle penetration of petroleum asphalt, modified asphalt, liquid petroleum asphalt, and residues after evaporation of emulsified asphalt.
Technical characteristics and performance
1.The Automatic Needle Penetration Test integrates new design concepts about penetrometer all over the world. It is advanced and delicate.
2. The Automatic Needle Penetration Test can make determination for needle penetration and cone penetration.
3. Controlled by a computer, it can make determination for needle penetration and cone penetration automatically. The test data are accurate and reliable.
4. The newly designed up and down assembly can be adjusted freely.
5. Equipped with automatic temperature controlling device and magnetic stirrer, so the bath temperature is uniform with high temperature controlling accuracy.
6. All parameters are shown on the LCD in real time.
7. Equipped with a micro-printer, so it can print out test data.
8. The Automatic Needle Penetration Test has a computer communication port to communicate with a computer.
Technical parameters of The Needle Penetration Test
1. Measurement range: 0~600 penetrati***;
2. Resolution: 0.1 penetrati***;
3. Timing selection: 0~60 s; Timing error is less than &plu***n;0.1 s;
4. Heating power: 200 W;
5. Temperature controlling accuracy: 25&plu***n;0.1 °C; (The ambient temperature should not be higher than 20 °C);
6. Data storage: 30 groups;
7. C***tant temperature bath: made of harden glass;
8. Stirrer: a magnetic stirrer;
9. Standard needle: 2.5&plu***n;0.05g; as per GB/T4509, and T0604;
10. Up and down holder: it contains fine adjustment and coarse adjustment assembly to let needle tip just contact with sample surface;
11. Power supply: AC 220V&plu***n;10%, 50 Hz;
12. Memory function: it can s***e 30 groups of test data;
13. Others: Equipped with light source and a magnifier, so it is convenient to be operated; the thermostatic device in the water bath is optional.